Data sheet
Wieland WRK
Finned copper tube heat exchanger for use with refrigerants
Wieland WRK Heat Exchangers are helical coils made with medium-high finned copper tube GEWA-D and flange mounting out of brass. The extruded fins on the outside and grooved inner surface optimizes the heat transfer.
The standard galvanic tin-plated outside surface reduces the corrosion risk of galvanized steel pipes connected downstream.
Type |
Max. conden- sation per- formance Q [kW]* |
Outer surface area [m2] |
Finned tube no. |
Tube length [mm] |
Volume refri- gerant side [liters] |
Dimensions [mm] |
Weight app. [kg] |
|||
---|---|---|---|---|---|---|---|---|---|---|
Dmax | amax | e | G | |||||||
WRK 4 | 3.0 | 0.4 | D-1135.12100-00 | 2,450 | 0.2 | 63 | 410 | 62 | 1/2" | 2.0 |
WRK 9 | 6.0 | 0.9 | D-1135.12100-00 | 4,800 | 0.4 | 140 | 350 | 62 | 1/2" | 3.5 |
WRK 13 | 8.5 | 1.3 | D-1135.14100-00 | 6,000 | 0.7 | 147 | 410 | 62 | 3/4" | 5.3 |
WRK 18 | 12.5 | 1.8 | D-1135.18100-00 | 6,950 | 1.5 | 170 | 440 | 65 | 1" | 7.5 |
WRK 23 | 16.0 | 2.3 | D-1135.18100-00 | 8,750 | 1.9 | 170 | 540 | 65 | 1" | 9.3 |
Available from stock. Customized design possible on request.
*Refrigerant R134a and ∆T = 25K (difference between condensation and water temperature)
Customized design
With customized series Wieland WRK flex additional flexible designs are available with suitable connecting parts or different tubes and materials for special applications like higher pressure situations.
Advantages
- Powerful at lowest temperature differences and pressure drop
- Enables buffer tank with highest COP-values
- High resistance against corrosion
- Hygienic material with antimicrobial properties
Applications
- Direct condensation or evaporation within the storage tank / domestic hot water tank
- Heat recovery of condensation heat from refrigerant applications
- Desuperheater in refrigeration
Operating range
- Max. operating pressure: 35 bar
- Max. operating temperature: up to + 150°C
Assembly instructions
As a rule, for the use as condenser / desuperheater the Wieland WRK is placed into the bottom part of the hot water tank. Its position may be horizontal or vertical. To avoid vibration failure, the finned tube heat exchanger should be braced in the tank not only for transportation but also in operation.
The mounting to the storage flange is by means of a hexagon nut and hollow disk (included). The seal is generally placed on the outside, but is also possible on the inside. When fixing the nut, it is necessary to counterhold at the fitting flats. Connected refrigerant pipes should be soldered to the pipe ends and fully absorb vibrations. A muffler should be mounted where the refrigerant vapour enters.
Electric insulation
Enameled hot water tanks are usually fitted with magnesium or impressed-current anodes to protect inadequately coated areas of the steel vessel against pitting corrosion. To maintain this protective effect, we recommend the use of insulation sets to ensure electrical separation of the heat exchanger from the storage tank. Retrofitting of hot water storage tanks is possible at any time.
Insulating set F
The insulating set F (for flange mounting) consists of an insulating sleeve and an insulating ring. For an outside seal it is fitted between the heat exchanger and the storage tank flange as shown in the figure. Alternately a sealing from the inside is possible. If the flange is less than 8 mm thick, a distance washer (not supplied with the set) should be positioned between the hollow disk and the hexagon nut. Insulating sets are accessories and are supplied on request, two sets are required per heat exchanger.
Part no. | Description | Material |
---|---|---|
1 | Finned tube GEWA-D | Cu-DHP | K21 |
2 | Connection | CuZn40Pb2 | Z48 |
3* | Insulating sleeve | PA |
4** | O-ring | EPDM |
5* | Insulating ring | POM-CE |
6 | Hollow disk | CuZn40Pb2 | Z48 |
7 | Hexagon nut | CuZn40Pb2 | Z48 |
* not supplied with the set | max. operating temperature: + 95°C
** max. operating temperature: + 130°C | do not use grease containing mineral oil
Quality Assurance
Responsibility begins with a high standard of quality. As the first company for semi-finished products in Europe, we have been on the path to certified quality management since 1987.
Today, we have DIN EN ISO 9001:2015 certifications for all producing plants, and our testing laboratories in Ulm and Vöhringen are additionally accredited to DIN EN ISO/IEC 17025:2018.
Pressure Equipment Directive
WRK heat exchangers correspond with the Pressure Equipment Directive 2014/68/EU. Our standard heat exchangers are leak-tested with an overpressure of 50 bar. On the refrigerant side, they are cleaned in accordance with DIN 8964, dried, filled with nitrogen and sealed with plastic caps.
Your contact for heat exchangers
Wieland Thermal Solutions
Heat exchangers