Data sheet
Wieland-GA9
Wieland-GA9 is a very soft material with the best emergency running properties. Use in case of insufficient lubrication. Well suited for water lubrication. However, the load capacity is not high; therefore mainly used in hydrodynamic applications.
Application: Underwater pumps.
Composition (standard values)
Pb 20 %
Sn 5 %
Ni 2 %
Cu balance
Material designation
Wieland GA9
EN 1982 : 1998
Max. load
Oscillating bearings up to 30 MPa
Types available
Machined bushings
Tube dimensions for machined bushings
continuously cast OD up to 200 mm
above pleaseenquire
Density [g/cm3] | 9.2 |
Coefficient of thermal extension (20 - 300 °C) [10-6/K] | 19.3 |
Thermal conductivity [W/m*K] | 70 |
Modulus of elasticity (20 °C) [GPa] | 80 |
Temper | |
Hardness [HB] | 55 |
Tensile strength Rm [MPa] | 200 |
0.2 %-proof stress Rp0.2 [MPa] | 120 |
Elongation A [%] | 14 |
1 MPa = 1 N/mm2